B-ALL Follow-Up Flow Panel

Code
FLT-BAFU-03BX
Panel
Active-Compendium
88184(x1), 88185(x14).
Clinical
Pathology
Bone Marrow Aspirate: 1-2 mL EDTA. Sodium heparin is acceptable. Lithium heparin or ACD (pale yellow/no gel separator) is not acceptable. Please provide recent CBC report.
Peripheral Blood: 1-2 mL EDTA. Sodium heparin is acceptable. Lithium heparin or ACD (pale yellow/no gel separator) is not acceptable. Please provide recent CBC report.
Fresh Bone Marrow Core Biopsy: 1-2cm core (length) tissue in RPMI
Fresh/Unfixed Tissue: 0.2 cm3 minimum in RPMI
Fluids and FNAs: Equal parts RPMI and specimen volume
CSF: 1-2 mL recommended
NY Clients: Please provide Date and Time of Collection.
Note: Please exclude biopsy needles, blades, and other foreign objects from transport tubes. These can compromise specimen viability and yield, and create hazards for employees.
Flag Active
True
Orderable Test Description
Available only as tech-only. Prior immunophenotyping at NeoGenomics with Standard or Extended Flow Panel is strongly recommended. Tech-only clients who push cases to global will be asked to provide previous flow cytometry report, previous pathology report, and/or clinical history notes. Markers are cCD3, CD5, CD10, CD11c, CD19, CD20, cCD22, CD23, CD34, CD45, cCD79a, kappa, lambda, cMPO, and nTdT (15 markers).
Orderable Turn Around Time
1 Day
Meta Description
The B-ALL Follow-Up Flow Panel is available at NeoGenomics for B-cell acute lymphocytic leukemia (B-ALL) monitoring after diagnosis is established. This is not a minimal residual disease panel since the standard number of events is collected.
Extra Note

Use cold pack for transport, making sure cold pack is not in direct contact with specimen. NYS clients please provide date and time of Collection.

NY Approved
True
Orderable Biomarkers JSON
{"Flow Cytometry": {"Markers": ["cCD79a", "CD23", "CD10", "CD20", "CD5", "lambda", "nTdT", "CD11c", "CD19", "cCD3", "cCD22", "Kappa", "CD34", "cMPO", "CD45"]}}
Keywords string
B-ALL, B-Cell ALL flow cytometry, B-ALL monitoring, B-ALL Follow-Up Flow Panel B-ALL Follow-Up Flow Panel
Title URL